AquaCalc DataLink 4 Release Notes and Updater Help

Please report bugs to:
Customer Support
support@aquacalc.com
 +1-916-372-0534
AquaCalc LLC
 JBS Instruments
www.aquacalc.com

Contents

Follow the links below to reach the topic of your choice. Help for the DataLink program can be found in the Section Explorer Help menu.

DataLink Release Notes and Change Report

How to Update the Firmware in your AquaCalc Pro Plus

How to Update the firmware in your older AquaCalc Pro

Troubleshooting Firmware Updates

AquaCalc Pro Plus Firmware Revision History

Older AquaCalc Pro Firmware Revision History

DataLink Release Notes and Change Report

Version 4.1.0 Released 02/28/2017

AquaCalc DataLink 4 requires a reinstall from our website or from the CD Setup files. We have updated the development environment to accomodate a change by Microsoft requiring a new Digital Signature using the SHA256RSA algorithm. See below.

Version 3.7.0 Released 10/27/15

Changes:

Version 3.6.0 Released 08/10/2015

Changes:

Version 3.5.0 Released 03/04/2015

Changes:

Version 3.4.0 Released 05/20/2014

Changes:

Version 3.3.2 Released 04/14/2014

Changes:

Version 3.3.1 Released 04/04/2014

Changes:

Version 3.2.1

Changes:

Version 3.1.1

Section Graphs / Section Report:

Version 3.1.0

Section Explorer screen:

Download Section Measurements Screen:

Settings Screen:

Other:

HKEY_CURRENT_USER/JBSEnergy/DataLinkApplicationPath HKEY_CURRENT_USER/JBSEnergy/DataLinkDownloadLogPath

Minor bug fixes including:

Fixed problem with dashes "-" and periods "." in Section ID causing problems with file paths.

Fixed problem with "Opening File location in Windows Explorer" in Section Explorer.

About screen now autosizes text areas.

 

Version 3.0.5 - Full Release To Market

Beta designation removed from Main Windows Explorer header

Help file updated

Version 3.0.3.x BETA

Changes include:

Version 3.0.2.x

Changes include:

Bug fixes:

Version 3.0.1.xx

DataLink Known Issues:

AquaCalc Pro Plus Firmware Updater Help

How to Update the Firmware in your AquaCalc Pro Plus

Troubleshooting

AquaCalc Pro Plus Revision History

Older AquaCalc Pro Revision History

The AquaCalc Pro Firmware Updater software will help you update the firmware in your AquaCalc Pro Plus to the current version.

WARNING: All Sections and observations in the AquaCalc Pro Plus may be lost when updating the firmware! Copy all data from the AquaCalc to your computer using the DataLink program.

How to Update the firmware in your AquaCalc Pro Plus

  1. Connect the AquaCalc Pro Plus to your computer's USB port using the AquaCalc's data cable.
  2. Run the AquaCalc Pro Firmware Updater Tool by selecting "AquaCalc Pro Firmware Updater" from DataLink's Tools menu.
  3. Follow the on-screen instructions in the Updater program.

Note: All AquaCalc 5000s, both the Basic and the Advanced, cannot use this update.

Selecting a firmware version to install.

Updater contains two versions of firmware. Normally this is the most current version of the firmware, and the previous version or a BETA version which has not completed testing. If you wish, you can select an older version to on the "Pro Plus" tab.

BETA firmware

DataLink may contain a BETA test version of the AquaCalc Pro Plus firmware instead of the previous version. This version of the firmware has completed testing at JBS, but needs volunteers to further test in the field. Select this only if you are willing to report any problems immediately to JBS.

>Troubleshooting

If your AquaCalc does not work properly after loading the new firmware, try loading the firmware again. If you continue to have problems, we encourage you to contact us using the information above.
If you receive a message in the AquaCalc's Diagnostic screen that reads "Upload FAILED":

AquaCalc Pro Plus Revision History

This section tracks the version releases and describes the bug fixes and the enhancements. Revisions are arranged in order of the latest first.

If you have any questions about this document or additions that you would like to see in the AquaCalc Pro, please contact JBS at (916) 372-0534 or jbs@jbsenergy.com. Please place the word "AquaCalc" in the subject line.

APP 2.2.0 BETA Dated 02/13/14 22:43 (Beta Release; Not completely tested).

APP 2.1.6 Dated 09/22/13 16:37

 Changes:

APP 2.1.5 Dated 11/18/12 17:07

 Changes:

  1. Minor Bug Fixes.
  2. Battery Meter Calibration
  3. Speed up key response time in Measure Screen.

APP 2.0.8 BETA Dated 08/04/2012

 Changes:

  1. Fixed bug where Custom Meters were not saved when AquaCalc Pro Plus was turned off.
  2. Calibration of Battery Level changed.

APP 2.0.7 BETA (Not Released)

APP 2.0.6 BETA Dated 06-24-2012

 Bug Fixes:

  1. Fix a bug where velocities were not calculated correctly in the Measure screen after changing from Price AA meter to Pygmy meter (Note: Section Totals and output velocities were not affected by this bug).

Known remaining problems:

The battery meter in version 2.0.6 BETA is still not calibrated correctly.

When there is 88% actual battery life remaining, the APP reports 62%.
When there is 51% actual battery life remaining, the APP reports 51%.
When there is 5% of actual battery life remaining, the APP reports 19%.

This is based on a 12 hour battery life. You should start to worry about low battery levels when the APP battery meter shows 20%.

APP rev 2.0.5 BETA Dated 05-06-2012

 Bug Fixes:

  1. Incorrect calculation of hanger bar lengths
  2. Incorrect meter coefficients used to calculated velocity in the Review Section Totals and during measurement.
  3. “Forgetting” meter coefficients in custom meters.
  4. Battery meter levels calibration.
  5. Section width calculation is wrong
  6. Incorrect times reported for observations.

How to Update the firmware in your AquaCalc Pro

  1. Connect the AquaCalc Pro to your computer's communication / serial port (COM port) using the AquaCalc's data cable.
  2. Run the AquaCalc Pro Firmware Updater Tool by selecting "Update AquaCalc Pro Firmware" from the DataLink > Tools Menu.
  3. Follow the on-screen instructions in the Updater program, selecting the "AquaCalc Pro" option in the first screen. The Updater "loads" the program into two places in the AquaCalc Pro: A "High" location and a "Low" location.

Note: All AquaCalc 5000s, both the Basic and the Advanced, cannot use this update.

Troubleshooting Firmware Updates

If your AquaCalc does not work properly after loading the new firmware, try loading the firmware again. If you continue to have problems, we encourage you to contact us using the information above.
If you receive a message in the AquaCalc's Diagnostic screen that reads "Upload FAILED":

 

AquaCalc Pro Revision History (Old Model)

AquaCalc Pro firmware rev 1.3.7 Dated 08-18-2008

 Additional Features:

  1. Ability to delete all observations but leave all vertical information. When a section is selected in the Sections screen the "Delete" option has been changed to "Delete Sect." (used to delete the entire section) and an additional option has been added: "Delete Obs.". When "Delete Obs." is selected, all of the observation information will be deleted from a section, but section information (gage id, meter info, etc.) and vertical information (individual distance and depth locations) are not deleted. This is useful when measurements are performed from the same tag-line positions each time, such as in pre-marked bridge locations.
  2. 0.2 Flood measurement is now properly enabled. In the Section Setup Screen when "8) .2 FLOOD" is selected, a line has been added "6) Flood Coef." where a coeffcient can be added that applies to all velocities performed at the 0.2 position. When performing flood measurements observations are only made at the 0.2 depth position across the entire section. A flood coefficient is used to aduste the observed velocity to represent the mean velocity. The usual 0.2 depth flood coefficent is about 0.87 but varies by stream. Please see the AquaCalc Pro manual "Performing Flood Measurements".
  3. Copy Horzontal Angle can now be set to copy only in the existing vertical. When 6) Copy Horiz. Angle is selected in the Vertical Setup screen, a second line appears that allows you to select "7) Same Vert. Only". The Horizontal Angle Coefficient is reset to a value of 1 when a New Vertical is created. This is now the default setting, so if you wish to use the same horizontal angle throughout a section, you must now turn off this feature.
  4. Inverted velocity in vertical warning message. The AquaCalc Pro now warns the user with an on-screen message when inverted vertical veleocities are found. Normal vertical will have higher velocities at the surface. Abnormal verticals may have higher velocities lower. When inverted velocities are found, the user should perform measurements in all three observtion location 0.2, 0.6, and 0.8.
    Improved Features:
  5. "Open Last" now opens the last section and returns to the last vertical in the section instead of the first vertical as in previous versions.
  6. Negative Offset values for the Current Meter constants are now allowed. Offset values from -6.0 to + 6.0 are now allowed. In previous versions negative offsets were not allowed.
  7. Changed the action of the Enter key in the Measure screen. Pressing the Enter key accidently, will not cause you to exit the Measure screen. Use the Menu key to return to the Main menu. Bug Fixes:
  8. Fixed un-intentional creation of new sections when the Re-Open Last softkey is used in the Main Menu and no vertical or section information entered. Under certain conditions, empty Sections would be created in previous firmware versions when using the "Re-Open Last" softkey.

AquaCalc Pro firmware rev 1.3.0 to 1.3.6 Not Released

AquaCalc Pro firmware rev 1.2.1 Dated 03-28-2006

Bug fixes and enhancements:
1) Fixed problems with metric conversions when using English / SAE rated current meters and measuring in metric

AquaCalc Pro firmware rev 1.1.4 Dated 11-16-05 Bug fixes and enhancements:

1) “LEW No” in header output changed to read "LEW"
2) Incorrect hanger bar length when using metric fixed: Now when System Preferences is set to "Metric" the values displayed for the hanger bar length are displayed in meters. In addition the bar length is adjusted into meters for the depth calculation.
3) Consistent navigation using keypad buttons: Navigation button functions changed to conform to the following:
-Menu button: Takes the user to the Main Menu Screen.
-Measure button: Takes user to the Measure screen
-Enter button: Moves up / back one level in hierarchy. (Exception: when the user presses ENTER from Section Setup or Vertical Setup Menus, they will be returned to the Measure Screen instead of to the Setup Screen.)
-Esc button: Not used in navigating through menus or screens. Used to cancel the entry of numbers and text and restore previous values when performing data entry. Values are displayed as "reversed" text light on a dark background when this function is available.
4) Replaced "1 of 2" with “More” and “2 of 2” with “Back” in soft-key menus.

AquaCalc Pro firmware rev 1.1.3 Dated 01-23-04

Bug fixes and enhancements:
1) Display contrast setting in Preference Menu is saved. Once you have selected a display contrast level in the Preference menu it will be the default setting until changed.
2) Lighter contrast extended for hotter weather (Pro should be kept in shade). The range of contrast control in the graphic display has been changed and extended to accomodate the changes made by the manufacture of the display.
3) Preferences Keypad Beep saved.
4) Entries for the Staff Heigh and the Gage Height have been extended from 99 to 9999 ft.
5) Change of Output file to Output version 1.5 due to item 4

AquaCalc Pro firmware rev 1.1.2

AquaCalc Pro firmware rev 1.1.1 Dated 06-11-03

 Bug fixes and enhancements:
1) Erase Obs now sets Horiz Coef to 1.0.
2) If all sections full AQP will not enter Meas Mode and signals user to delete sections.
3) Section Data is saved from volatile memory to flash memory every time a new vertical is created.
4) Nostandard meter selection bug fix. --------------------------

AquaCalc Pro firmware rev 1.0.10 Dated 04-30-03

Bug fixes and enhancements: 
Bug fix nonstandard meters

AquaCalc Pro firmware rev 1.0.9 Dated 04-04-03

Bug fixes and enhancements:
1) Bug fix assembly date changed from 2002 to 2003
2) Bug fix for user selected sounding weight tag distance.
3) Addition of 3 optical meter types user selectable. To use this feature, from the main menu select 4, Meter Setup. The first three meters available without configuration are the default standard group: Price AA 1-1 rating standard 2, Pygmy rating standard 2, and Price AA 5-1 rating standard 2. The next seven meters can be configured by the user. In addition there are 3 optical meters available to select from using the 3) Type selection in the EDIT METER screen they are: Price AA USGS Optical 1-4 standard 2, Price AA Gurley Optical 1-2 standard 2, and Pygmy Gurley Optical 1-2 standard 2. --------------------------

AquaCalc Pro firmware rev 1.0.8 Dated 01-30-03

Bug fixes and enhancements:
1) This update fixes the rounding problem when summing the subsection values and calculating the totals.

AquaCalc Pro firmware rev 1.0.7 Dated 11-22-02

 Bug fixes and enhancements:
 1) Low battery check disabled during power-down
2) Enter key to return from "Meas > Setup" menu
3) Enter key to return from "Meas > Setup > Vertical Setup" menu
4) Measure time calculated
5) Insert Vertical moves to Inserted Vertical
File format modifications (File format Version: "V1.4")
1) measure time x.xx hours added to header data (NA if dates don't equal)
2) vertical area increased to 100th

AquaCalc Pro firmware rev 1.0.6 Dated 10-11-02 fixes and enhancements:

1) Horizontal angle calculation in the download has been corrected. In the downloaded file the output displayed both the horizontal angle "HA" and the cosine coefficient (HC) of the horizontal angle "HC:VF" were incorectly displayed. The horizontal angle coefficient was always correctly displayed and correctly adjusted the velocity. However, the horozontal angle HA was not correctly represented in the output creating confusion.
2) Observation "Time Stamps" are now included on all observations including walls and edge of water.
3) Additional entry in the sounding weight list "User 0.00", allows the user to use any sounding weight without the hanger bar adjustment being automatically added to the depth. The value of the sounding weight on the output is a blank "_____".
4) Measurement syncronization problem has been enhanced. 5) Meter setup table protected from accidently editing an existing nonstandard meter.

AquaCalc Pro firmware rev 1.0.5 Dated 04-18-02

Bug fixes and enhancements:
1) Bug fix: Auto power-down hang condition resolved
2) Measure screen includes "Prev.Vert. %Q: x.xx" on display line 14. This value allows user to view %Q of previous vertical when adjusting tagline distance
3) Bug fix: AQPro freezes operation when invoking "Swap Observation" command problem resolved --------------------------

AquaCalc Pro firmware rev 1.0.4 Dated 04-12-02

Bug fixes and enhancements:
1. Bug fix for User Entry of Staff Gage height.
2. Return to Section Setup Menu after Meter Select key is pressed.
3. Firmware version changed to AQP-1V1.0.4 --------------------------

AquaCalc Pro firmware rev 1.0.3 Dated 02-13-02

Bug fixes and enhancements:
1) Addition of meter setup menu for 10 meters
2) Addition of the capability to swap Observations
3) Date and Timestamps changed per request
4) Text entries are now left justified
5) Measure time from 0-250 seconds properly displayed
6) Error beep when invalid Meas. Options are pressed
7) Bug fix: Price AA max depth set to 0.00
File format modifications (File format Version: "V1.3")
1) Meter Revs/Pulses ratio added
2) Meter type added
3) Meter std added
4) HEX byte 1A added to end of upload file

AquaCalc Pro firmware rev 1.0.2 Dated 01-31-02

Bug fixes and enhancements:
1) Addition of meter edit screen
2) Modified the Display of Revs and Time
3) Added Move Observation
4) Fixed escape keys
5) Left justify text entry
6) Bug fix Fixed a rounding problem
5) Added measurement quality to the output screen with a menu item.
File format modifications (File format Version: "V1.2")
1) Added measurement quality to the output file.

 

Prepared by: Greg Ruszovan
Prepared On: February 24, 2014

Copyright 2016,2017